Centrifugal Fans for Power Stations/ Industrial Boilers

Having been sold to many domestic and global places over the past two decades, YUTONG blowers are always highly spoken of thanks to YUTONG’s long-term tenet of “Good quality brings more orders”, people oriented
Y8-39/Y9-38 Induced Draft Fan for Boilers

Y8-39/Y9-38 Induced Draft Fan for Boilers

This blower applies to 0.5-35t/h industrial boilers equipped with economizer (pre-heating device) and dust removal devices. All industrial boilers with similar inlet conditions and right performance can use such blowers. But the air inlet temperature may not exceed 250℃.

Get Price Send Messages
Product Description

This blower applies to 0.5-35t/h industrial boilers equipped with economizer (pre-heating device) and dust removal devices. All industrial boilers with similar inlet conditions and right performance can use such blowers. But the air inlet temperature may not exceed 250℃.

Dust removal device with de-dusting efficiency of not lower than 85% shall be installed before induced draft fans to minimize the dust content entering blowers. This not only reduces environmental pollution, but also lower blower wearing caused by dust, improving blowers’ service life.

Key Advantages:

1. Impellers- They are composed of long and short front-curved Q345 (16Mn) blades. After static and dynamic balance correction, this blower enjoys stable operation.

2. Casing-It is a volute casing made of welded steel plates. It has a dust cleaning door, which is easy for workers to remove the dust fallen on impellers and inside blower casing and thus ensures impellers’ balance and aerodynamic performance.

3. Air inlet- With convergent and streamlined integrated design, the air inlet is fixed to front cover plate with screws.

4. Air damper-The air damper has petal-design blades and are axially mounted before the air inlet. Fans with No. 4-6.3 have 9 blades for air dampers while fans with No. 8 and upper series have 11 blades for air dampers. Thanks to the outside driving structure, they enjoy flexible and easy rotation. The adjusting range is from 0° (fully open) to 90° (fully closed). Looking from the side of the air inlet, the handle of the air damper is on the right side. For right rotation blowers, the handle moves from fully closed to fully open by moving from bottom to top. For left rotation blowers, the handle moves from fully closed to fully open by moving from top to bottom. Air damper has to be lubricated carefully to ensure its normal operation. Blowers apply temperature-resistant (260℃) lubrication grease for lubrication, ensuring good lubrication under high temperature operation.

5. Driving system-The driving system consists of main shaft, water cooling bearing box and coupling, etc. The main shaft is made of quality steel and the bearing is rolling bearing. The bearing box has both integrated type and separate type. Blowers with No.4~No.6.3 apply integrated type bearing box while blowers with No.4~No.6.3 apply water cooling integrated bearing box. Both bearing boxes need cooling water; water consumption varies with ambient temperature and is usually considered as 0.5-1m3/h. Equipped with thermometer and oil level indicator, the bearing box uses L-AN46 (Lubricating Oils for Total Loss Systems L-AN). The oil amount to be added shall be based on the oil level indicator.

Specification:

Item name

Y8-39/Y9-38 Induced Draft Fan for Boilers

Parts details

Impeller diameter

400~1600

mm

Speed of main shaft

730~2900

r/min

Pressure range

1157~5805

Pa

Flow range

3242~110666

m3/h

Structure

Blade structure

Forward

Impeller support

Single support

Drivetrain

C/D

Assignable

Lubrication

Oil bath lubrication / grease lubrication

Assignable

Bearing cooling

Circulation water cooling/air cooling

 

Circulation oil cooling

 

System
configuration

Motor

Anhui Wannan, Lu’an Jianghuai, Henan Yutong, Jiamusi, Nanyang Explosion Proof, Siemens

 

Impeller, air inlet, blower casing, air damper

Carbon steel

Customizable

Main shaft

High strength carbon structure

Bearing

FAG, SKF, ZWZ, C&U,YLC…

Bearing box

Casting iron

 

Drivetrain

Coupling/ belt pulley

Assignable

Foundation bolt

Carbon steel

 

Optional
parts

System base frame, Protective screening, Silencer, Inlet& outlet pipeline compensator, Inlet& outlet flange, Air damper, Electric actuator, Shock isolator, Diaphragm coupling, Fluid coupling, Motor rain cover, Temperature sensor, Vibrating sensor, Soft starter, Variable-frequency drive, Special motor, System monitoring &control instrument, Lubrication system and High-level oil tank.

 

Applications:

They are applicable to normal temperature and hot gas, clean and dusty gas, powder materials and tiny granules. They can apply into boilers, dust removal, de-nitration and desulfurization, cement, metallurgy, power generation, gas and material handling, smoke exhausting. It can also be customized according to special industries.

Related Products
Inquiry

Get Price And Support

Please feel free to inquire us in the form below.